Add to MyChemicals Print Friendly Page
Chemical Datasheet

CALCIUM PEROXIDE

5.1 - Oxidizer
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.

UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.

DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.

CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.

NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and instability hazards, along with special hazards such as water- and air-reactivity. See a guide to the NFPA diamond.

General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.

List of data sources.
CAS Number UN/NA Number DOT Hazard Label CHRIS Code
  • 1305-79-9
  • Oxidizer
NFPA 704
data unavailable
General Description
A grayish white granular material. Used in baking, in medicine, in bleaching oils.

Hazards

Reactivity Alerts - Special alerts if the chemical is especially reactive (see list of reactivity alerts).

Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.

Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).

Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).

Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).

Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.

Potentially Incompatible Absorbents - Absorbents are products that can be used to soak up liquids from spills. However, some absorbents can react with particular chemicals (that is, they are incompatible), so caution should be used in selecting the correct absorbent for your situation. This section provides a list of potentially incompatible absorbents that have been known to react with liquids assigned to one or more of the reactive groups listed on this datasheet. Read more about absorbents, including situations to watch out for.

List of data sources.
Reactivity Alerts
Air & Water Reactions
Isoluble in water and slowly decomposed by water to produce calcium hydroxide (slaked lime) [Sax, 9th ed., 1996, p. 636].
Fire Hazard
Behavior in Fire: Can increase severity of fire. Containers may explode. (USCG, 1999)
Health Hazard
Inhalation of dust irritates nose and throat. Dust also irritates eyes and skin on contact and irritates mouth and stomach if ingested. (USCG, 1999)
Reactivity Profile
CALCIUM PEROXIDE is an explosion hazard if mixed with finely divided organic matter. Noncombustible but accelerates the burning of combustible material: mixtures of combustible material and the peroxide can be ignited by friction or contact with moisture. Mixtures with polysulfide polymers may ignite. Decomposes rapidly above 200° C. Strongly basic. Reacts with water to produce calcium hydroxide (slaked lime) [Sax, 9th ed., 1996, p. 636].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

Response Recommendations

Isolation and Evacuation - Isolation and evacuation distance recommendations from the Emergency Response Guidebook (ERG).

Firefighting - Response recommendations if the chemical is on fire (or near a fire).

Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).

Protective Clothing - Recommendations for protective gear.

Dupont Tychem® Suit Fabrics - A table of normalized breakthrough times for DuPont Tychem suit fabrics for the chemical, if available.

First Aid - Recommended first aid treatment for people exposed to the chemical.

List of data sources.
Isolation and Evacuation
Excerpt from GUIDE 140 [Oxidizers]:

As an immediate precautionary measure, isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2012)
Firefighting
Excerpt from GUIDE 140 [Oxidizers]:

SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. Move containers from fire area if you can do it without risk.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2012)
Non-Fire Response
Excerpt from GUIDE 140 [Oxidizers]:

Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Do not get water inside containers.

SMALL DRY SPILL: With clean shovel place material into clean, dry container and cover loosely; move containers from spill area.

SMALL LIQUID SPILL: Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Following product recovery, flush area with water. (ERG, 2012)
Protective Clothing
U.S.B.M. -approved toxic dust respirator; general-purpose gloves; chemical safety goggles; full cover clothing. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION: remove to fresh air.

EYES: flush with water for 15 min. and consult physician.

SKIN: flush with water.

INGESTION: give large amounts of water. (USCG, 1999)

Physical Properties

This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see definitions of each property). More property data is available for common chemicals.

See also the Levels of Concern guide for information on AEGLs, ERPGs, PACs, and IDLH values.

List of data sources.
Chemical Formula:
  • CaO2
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 2.92 at 77.0 ° F (USCG, 1999)
Boiling Point: data unavailable
Molecular Weight: 72.1 (USCG, 1999)
Water Solubility: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

No PAC information available.

Regulatory Information

This section contains regulatory information from the Title III Consolidated List of Lists (see details about each regulatory field).

List of data sources.
No regulatory information available.

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.