Add to MyChemicals Print Friendly Page
Chemical Datasheet

CUMENE

3 - Flammable liquid
Chemical Identifiers | Hazards | Response Recommendations | Physical Properties | Regulatory Information | Alternate Chemical Names

Chemical Identifiers

CAS Number - Chemical Abstracts Service registry number. Unique identification number assigned to this chemical by the American Chemical Society.

UN/NA Number - The United Nations-North America number (also called UN number or DOT number). 4-digit number identifying an individual chemical or group of chemicals with similar characteristics. Required on shipping papers; often shown on placards or labels. This numbering system was developed by the U.S. Department of Transportation, and then became the UN standard system for classifying hazardous materials.

DOT Hazard Label - U.S. Department of Transportation hazard warning label for the chemical (such as flammable liquid or corrosive). This label must be displayed on shipped packages, railroad tank cars, and tank trucks according to specifications described in 49 CFR 172.

CHRIS Code - 3-letter code used by the U.S. Coast Guard to identify individual chemicals included in its CHRIS (Chemical Hazards Response Information System) manual.

NFPA 704 - Text description of the diamond-shaped placard, which contains codes indicating the level of the chemical's health, flammability, and instability hazards, along with special hazards such as water- and air-reactivity. See a guide to the NFPA diamond.

General Description - Brief description of the chemical's general appearance, behavior, and hazardousness.

List of data sources.
CAS Number UN/NA Number DOT Hazard Label CHRIS Code
  • 98-82-8   (CUMENE)
  • Flammable Liquid
NFPA 704
Diamond Hazard Value Description
3
2 1
Blue Health 2 Can cause temporary incapacitation or residual injury.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 1 Normally stable but can become unstable at elevated temperatures and pressures.
White Special
(NFPA, 2010)
General Description
A clear colorless liquid with an aromatic odor. Flash point 115°F. Less dense than water and insoluble in water. Vapors heavier than air. May be moderately toxic by inhalation, ingestion and skin absorption.

Hazards

Reactivity Alerts - Special alerts if the chemical is especially reactive (see list of reactivity alerts).

Air & Water Reactions - Special alerts if the chemical reacts with air, water, or moisture.

Fire Hazard - Description of the chemical's fire hazards (such as flammability, explosion risk, or byproducts that may evolve if the chemical is burned).

Health Hazard - Description of the chemical's health hazards (such as toxicity, flammability, or corrosivity).

Reactivity Profile - Description of the chemical's potential reactivity with other chemicals, air, and water. Also includes any other intrinsic reactive hazards (such as polymerizable or peroxidizable).

Reactive Groups - List of reactive groups that the chemical is assigned to, based on its known chemistry. Reactive groups are categories of chemicals that react in similar ways because their chemical structures are similar. Reactive groups are used to predict reactivity when you add a chemical to MyChemicals. Read more about reactive groups.

Potentially Incompatible Absorbents - Absorbents are products that can be used to soak up liquids from spills. However, some absorbents can react with particular chemicals (that is, they are incompatible), so caution should be used in selecting the correct absorbent for your situation. This section provides a list of potentially incompatible absorbents that have been known to react with liquids assigned to one or more of the reactive groups listed on this datasheet. Read more about absorbents, including situations to watch out for.

List of data sources.
Reactivity Alerts
none
Air & Water Reactions
Flammable. Insoluble in water.
Fire Hazard
Excerpt from GUIDE 130 [Flammable Liquids (Non-Polar / Water-Immiscible / Noxious)]:

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water. (ERG, 2012)
Health Hazard
Narcotic action with long-lasting effects; depressant to central nervous system. (USCG, 1999)
Reactivity Profile
Mixing CUMENE in equal molar portions with any of the following substances in a closed container caused the temperature and pressure to increase: chlorosulfonic acid, nitric acid, oleum, NFPA 1991.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

Response Recommendations

Isolation and Evacuation - Isolation and evacuation distance recommendations from the Emergency Response Guidebook (ERG).

Firefighting - Response recommendations if the chemical is on fire (or near a fire).

Non-Fire Response - Response recommendations if the chemical isn't on fire (or near a fire).

Protective Clothing - Recommendations for protective gear.

Dupont Tychem® Suit Fabrics - A table of normalized breakthrough times for DuPont Tychem suit fabrics for the chemical, if available.

First Aid - Recommended first aid treatment for people exposed to the chemical.

List of data sources.
Isolation and Evacuation
Excerpt from GUIDE 130 [Flammable Liquids (Non-Polar / Water-Immiscible / Noxious)]:

As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2012)
Firefighting
Excerpt from GUIDE 130 [Flammable Liquids (Non-Polar / Water-Immiscible / Noxious)]:

CAUTION: All these products have a very low flash point: Use of water spray when fighting fire may be inefficient.

SMALL FIRE: Dry chemical, CO2, water spray or regular foam.

LARGE FIRE: Water spray, fog or regular foam. Do not use straight streams. Move containers from fire area if you can do it without risk.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2012)
Non-Fire Response
Excerpt from GUIDE 130 [Flammable Liquids (Non-Polar / Water-Immiscible / Noxious)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor; but may not prevent ignition in closed spaces. (ERG, 2012)
Protective Clothing
Skin: Wear appropriate personal protective clothing to prevent skin contact.

Eyes: Wear appropriate eye protection to prevent eye contact.

Wash skin: The worker should immediately wash the skin when it becomes contaminated.

Remove: Work clothing that becomes wet should be immediately removed due to its flammability hazard(i.e. for liquids with flash point < 100°F)

Change: No recommendation is made specifying the need for the worker to change clothing after the work shift. (NIOSH, 2003)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QC = Tychem QC
SL = Tychem SL
TF = Tychem F
TP = Tychem ThermoPro
C3 = Tychem CPF 3
BR = Tychem BR
LV = Tychem LV
RC = Tychem Responder® CSM
TK = Tychem TK
RF = Tychem Reflector®
Testing Details
Permeation data obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate is equal to 0.1 µg/cm2/min) reported in minutes. All liquid chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated. Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QC SL TF TP C3 BR LV RC TK RF
Cumene 98-82-8 Liquid >480 >480 364 >480 >480 >480 >480 >480
> indicates greater than.
A blank cell indicates the fabric has not been tested. The fabric may or may not offer barrier.

Special Warnings from DuPont

  1. Serged and bound seams are degraded by some hazardous liquid chemicals, such as strong acids, and should not be worn when these chemicals are present.
  2. CAUTION: This information is based upon technical data that DuPont believes to be reliable. It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability...
    ... in connection with this information. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact DuPont for specific data. If fabric becomes torn, abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, we make no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its use.

(DuPont, 2013)

First Aid
Eye: If this chemical contacts the eyes, immediately wash the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately. Contact lenses should not be worn when working with this chemical.

Skin: If this chemical contacts the skin, flush the contaminated skin with water promptly. If this chemical penetrates the clothing, immediately remove the clothing and flush the skin with water promptly. If irritation persists after washing, get medical attention.

Breathing: If a person breathes large amounts of this chemical, move the exposed person to fresh air at once. If breathing has stopped, perform mouth-to-mouth resuscitation. Keep the affected person warm and at rest. Get medical attention as soon as possible.

Swallow: If this chemical has been swallowed, get medical attention immediately. (NIOSH, 2003)

Physical Properties

This section contains physical properties, flammability limits, and toxic thresholds for this chemical (see definitions of each property). More property data is available for common chemicals.

See also the Levels of Concern guide for information on AEGLs, ERPGs, PACs, and IDLH values.

List of data sources.
Chemical Formula:
  • C9H12
Flash Point: 96 ° F (USCG, 1999)
Lower Explosive Limit (LEL): 0.9 % (USCG, 1999)
Upper Explosive Limit (UEL): 6.5 % (USCG, 1999)
Autoignition Temperature: 797 ° F (USCG, 1999)
Melting Point: -140.9 ° F (USCG, 1999)
Vapor Pressure: 25.85 mm Hg (USCG, 1999)
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 0.866 at 59.0 ° F (USCG, 1999)
Boiling Point: 306.3 ° F at 760.0 mm Hg (USCG, 1999)
Molecular Weight: 120.19 (USCG, 1999)
Water Solubility: Insoluble (NIOSH, 2003)
IDLH: 900 ppm Based on 10% of the lower explosive limit. (NIOSH, 2003)

AEGLs (Acute Exposure Guideline Levels)

Interim AEGLs for Cumene (98-82-8)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes 50 ppm 550 ppm 1300 ppm
30 minutes 50 ppm 380 ppm 920 ppm
60 minutes 50 ppm 300 ppm 730 ppm
4 hours 50 ppm 190 ppm 460 ppm
8 hours 50 ppm 130 ppm 300 ppm
Level of Distinct Odor Awareness (LOA) = 0.017 ppm
(NAC/NRC, 2013)

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Cumene; (Isopropyl benzene) (98-82-8) 50 ppm 300 ppm 730 ppm LEL = 8000 ppm
(SCAPA, 2012)

Regulatory Information

This section contains regulatory information from the Title III Consolidated List of Lists (see details about each regulatory field).

List of data sources.
Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Cumene 98-82-8 5000 313 U055

(EPA List of Lists, 2012)

Alternate Chemical Names

This section provides a listing of alternate names for this chemical, including trade names and synonyms.